Sealed system pressurisation

Commercial Pressurisation Unit Repairs in London

Low-pressure alarms, failed pressurisation pumps, expansion vessel problems and control faults on sealed heating and chilled water systems.

  • 24/7 contact line
  • London & Greater London
  • Commercial buildings only
Engineer in a high-visibility jacket carrying a tool case along a wet London riverside towards a commercial building, with the Shard in the background
Illustrative image

In short

A pressurisation unit keeps a sealed heating or chilled water system at the right pressure. When it fails or alarms, system pressure can fall and boilers lock out, or pressure can rise and safety valves discharge. Record the pressure reading and alarm, do not adjust settings or valves, and call a commercial engineer to find the cause, which is often a leak or vessel fault.

Is it urgent?

Call now if

  • Boilers have locked out on low system pressure
  • The pressurisation unit is in alarm and pressure keeps falling
  • Safety valves are discharging or pressure is abnormally high
  • The unit is running constantly, suggesting a significant leak
Call 020 7998 9005

Usually suitable for scheduled work

  • The unit tops up occasionally and pressure holds
  • A minor alarm that has cleared with pressure normal
  • Annual servicing of the unit and expansion vessels
Send an enquiry instead →

What pressurisation units do

Sealed commercial heating and chilled water systems need a minimum pressure to keep water from boiling, protect pumps and allow boilers to operate. Pressurisation units top up water from a break tank to hold that pressure, while expansion vessels absorb thermal expansion.

Common faults

Symptom Possible causes
Low-pressure alarm, boilers locked out Leak, failed unit pump, empty break tank, failed controls
Unit tops up very often Leak, passing safety valve or air vent, failed expansion vessel
High pressure, safety valve discharging Expansion vessel failure, overfilling, control fault
Unit in fault, will not run Pump failure, electrical fault, low break tank level

Commercial heating system pressure problems

Pressure loss can lock out every boiler in a plant room at once. See commercial boiler repairs and plant room repairs.

Safe inspection and isolation

Sealed systems contain hot water under pressure. Do not open valves, drain points or vessel connections, and do not change unit settings. Scalding and flooding are real risks.

Professional repair

The engineer checks the unit, break tank, pumps, controls, expansion vessels and safety valves, then looks for where water is being lost. Finding and fixing the leak matters as much as fixing the unit. See commercial pipework repairs.

Water quality

Frequent topping up dilutes water treatment and brings in fresh oxygen, which increases corrosion. After repairs, ask for system water treatment to be checked.

Pressurisation Unit Repairs: frequently asked questions

Pressurisation unit alarm. What should Facilities Managers check and report?

Note the alarm message, the system pressure gauge reading and the unit's set pressure if shown, whether boilers have locked out, whether the unit is running or topping up frequently, and any signs of leaks in the plant room or building. Do not change settings or open valves.

Why does system pressure keep dropping?

Usually because water is leaving the system through a leak, a passing safety valve or an automatic air vent. A failed expansion vessel can also cause pressure to swing. The pressurisation unit is often reporting a problem elsewhere rather than being the fault itself.

What does an expansion vessel do?

It absorbs the increase in water volume as the system heats up. If its air charge is lost or the membrane fails, pressure rises when hot and falls when cool, causing safety valves to discharge and the unit to top up repeatedly.

Can low pressure damage boilers and pumps?

Boilers are protected by low-pressure lockouts. Pumps can cavitate or run dry if pressure is too low, causing damage. That is one reason to treat persistent low pressure promptly.

Do pressurisation units need servicing?

Yes. Pumps, controls, break tanks, expansion vessel charge and safety devices should be checked as part of planned maintenance. Some pressure equipment falls under the Pressure Systems Safety Regulations, so check with your competent person.

UK guidance and references

Primary and industry sources relevant to this subject. Always check the current edition and how it applies to your building.

Online enquiry

Request Emergency Assistance

For urgent assistance, call 020 7998 9005. Online enquiries are not a substitute for immediate emergency contact.

Use this form for time-sensitive repairs, scheduled assessments and general enquiries, or to send photos and details after you have called. Enquiries go to the Flair Facilities team at info@flairfacilities.co.uk.

Suspected gas escape or carbon monoxide: leave the area and call the National Gas Emergency Service on 0800 111 999. Do not use this form.

  • Selecting "Urgent" does not dispatch an engineer: availability is confirmed by the team
  • No marketing sign-up: details are used to respond to this enquiry
  • See our privacy policy

Fields marked with an asterisk are required.

Full UK postcode, for example EC1V 2NX
For an urgent operational breakdown, please also call.
What has happened, when it started, any fault codes or alarms, and which areas are affected (at least 20 characters).
On-site contact, plant room location, parking, permits or induction requirements.

We use these details only to respond to this enquiry. We do not add you to marketing lists.